electrical wiring diagram for water pump motor set PPC Multimotor Control Model Water Level Controller Installation 14 Most Electrical Wiring Diagram, Water Pump Motor Set Ideas

14 Most Electrical Wiring Diagram, Water Pump Motor Set Ideas

Galleries photos in this diagram:

Other recommended photos you might like:

Electrical Wiring Diagram, Water Pump Motor Set - Copper strength cable of about 2 to 6 meters as in line with requirement. Line tester. Insulation tape, necessary screws and wood gattas pieces for mounting controller unit at the wall. Cutting pliers or nose pliers. Simple hammer-jumper set or drill gun to mount the level controller to wall or to wood board.

Step 1. Put off the lowest cap of the water stage controller and discover the coloured sensing cord bunches on the lowest opening of the unit. Step 2. The sensing wires accommodates of bunches of wires, one bunch of 3 wires(and a pair of thin twine) for sump or decrease tank and every other bunch of 5 wires for top tank. Step three. Do whole sensing wiring from water degree controller to overhead tank and water stage controller to underground sump / well. Step 4. To attach the sensing wires of tank and sump / nicely, to the water degree controller unit, truely twist the wires to the respective wires of water degree controller unit within the following manner. Slide the black % sleeve supplied over the twisted joint completely. The gain of having unfastened sensing cord over the sensing terminal block is that, loose contacts are avoided and checking out of the controller features can be finished without difficulty by way of shorting the sensing wires of controller without delay. Step five. Oh tank sensing reference to bunch of five wires: -.

Vital: the sensing cord from the unit to oh tank and unit to ug sump / properly have to be a one-piece twine and there should be virtually no joints in these sensing wires and those wires have to now not be damaged in any manner. Unit will not perform successfully in these cases. Continuity of cord need to be checked earlier than twine is laid. This sensing twine can be put interior percent pipe all through for additonal protection.

Maintain the delay wires (skinny wires) open earlier than checking out method. Now positioned both car/manual switches of the the level controller in automated mode and placed the mode selector transfer (small switch on righthand aspect pinnacle) to car mode. Oh tank checking out system for ug sump pumpset: step 1. Immerse all three ug sump sensing probes inside the ug sump water. Step 2. Then start testing the oh tank function. This may be performed by using immersing and lifting of the sensor association within the oh tank water. Step 3. In oh tank, elevate slowly both pump on sensor and pump off sensor above water degree. Now the ug sump pumpset ought to start pumping. Step 4. Now immerse most effective pump on sensor within the water, now ug sump pumpset have to retain to pump. Step 5. Now immerse pump off sensor also within the water, now ug sump pumpset should switch off immediately. Step 6. Now lift only pump off sensor from the water, ug sump pumpset need to stay off. Step 7. Now also raise pump on sensor from the water, now ug sump pumpset must activate again. Step 8. Repeat the steps from step 4 to step 7 for 4 to 5 times to make sure the precise operations. Step 9. To check the waft sensor, put off the joint of flow sensor to brown wire, hold the brown cord outside water and lift each on and stale sensor probes from the water to replace on the pump. Now be part of returned the flow sensor wires to brown cord quickly. Step 10. Now wait for two mins to find that pump receives robotically switched off and take a look at that stage controller will be showing "dry run" indication of ug sump pumpset in conjunction with beep sound. Step eleven. Now oh tank trying out of ug sump pumpset is finished. Now preserve the extent sensing probes inside the ug sump outside the water to check borewell pumpset. Step 12. Now, in oh tank, elevate slowly each pump on sensor and pump off sensor above water level. Now the borewell pumpset ought to begin pumping. Step 13. Now immerse simplest pump on sensor in the water, now borewell pumpset need to keep to pump. Step 14. Now immerse pump off sensor additionally within the water, now borewell pumpset need to transfer off right now. Step 15. Now carry only pump off sensor from the water, borewell pumpset must remain off. Step sixteen. Now additionally carry pump on sensor from the water, now borewell pumpset should activate again. Step 17. Repeat the stairs from step eleven to step 15 for four to 5 times to ensure an appropriate operations. Step 18. To test the flow sensor once more in borewell mode, get rid of the joint of go with the flow sensor wire to brown wire, maintain the brown twine out of doors water and raise each on and stale sensor probes from the water to interchange on the pump. Step 19. Now wait for 2 mins to locate that pump receives routinely switched off and take a look at that level controller could be showing "dry run" indication along side beep sound. Step 20. Now oh tank testing is finished. Join again the brown wire to flow sensor wires and now insulate it with the insulation tape.